-  Status script+ 
 +  Test utilities
 <WRAP prewrap center> <WRAP prewrap center>
 <code> <code>
 +# /sbin/hplog -t -f -p
 +
 +ID     TYPE        LOCATION      STATUS    CURRENT  THRESHOLD 
 +  Basic Sensor Ambient         Normal    66F/ 19C 107F/ 42C 
 +  Basic Sensor Processor Zone  Normal   104F/ 40C 158F/ 70C 
 +  Basic Sensor Processor Zone  Normal   104F/ 40C 158F/ 70C 
 +  Basic Sensor Processor Zone  Normal   104F/ 40C 158F/ 70C 
 +  Basic Sensor Processor Zone  Normal   104F/ 40C 158F/ 70C 
 +  Basic Sensor Memory Board    Normal   ---F/---C 188F/ 87C 
 +  Basic Sensor Memory Board    Normal    91F/ 33C 188F/ 87C 
 +  Basic Sensor Memory Board    Normal   ---F/---C 188F/ 87C 
 +  Basic Sensor Memory Board    Normal    89F/ 32C 188F/ 87C 
 +10  Basic Sensor Memory Board    Normal   ---F/---C 188F/ 87C 
 +11  Basic Sensor Memory Board    Normal    84F/ 29C 188F/ 87C 
 +12  Basic Sensor Memory Board    Normal   ---F/---C 188F/ 87C 
 +13  Basic Sensor Memory Board    Normal    84F/ 29C 188F/ 87C 
 +14  Basic Sensor System Board    Normal    95F/ 35C 140F/ 60C 
 +15  Basic Sensor System Board    Normal   111F/ 44C 221F/105C 
 +16  Basic Sensor Pwr. Supply Bay Normal    80F/ 27C ---F/---C 
 +17  Basic Sensor Pwr. Supply Bay Normal    82F/ 28C ---F/---C 
 +18  Basic Sensor Pwr. Supply Bay Normal    96F/ 36C 167F/ 75C 
 +19  Basic Sensor System Board    Normal   105F/ 41C 239F/115C 
 +20  Basic Sensor System Board    Normal   107F/ 42C 239F/115C 
 +21  Basic Sensor System Board    Normal   102F/ 39C 239F/115C 
 +22  Basic Sensor System Board    Normal   102F/ 39C 239F/115C 
 +23  Basic Sensor System Board    Normal    89F/ 32C 176F/ 80C 
 +24  Basic Sensor System Board    Normal   113F/ 45C 239F/115C 
 +25  Basic Sensor System Board    Normal   109F/ 43C 239F/115C 
 +26  Basic Sensor System Board    Normal   111F/ 44C 239F/115C 
 +27  Basic Sensor System Board    Normal    98F/ 37C 239F/115C 
 +28  Basic Sensor System Board    Normal    93F/ 34C 239F/115C 
 +29  Basic Sensor System Board    Normal    93F/ 34C 239F/115C 
 +30  Basic Sensor System Board    Normal    93F/ 34C 239F/115C 
 +31  Basic Sensor System Board    Normal    91F/ 33C 239F/115C 
 +32  Basic Sensor System Board    Normal   147F/ 64C 212F/100C 
 +33  Basic Sensor System Board    Normal   107F/ 42C 176F/ 80C 
 +34  Basic Sensor I/O Zone        Normal   ---F/---C 212F/100C 
 +35  Basic Sensor I/O Zone        Normal   ---F/---C 212F/100C 
 +36  Basic Sensor I/O Zone        Normal   ---F/---C 212F/100C 
 +37  Basic Sensor I/O Zone        Normal   ---F/---C 212F/100C 
 +38  Basic Sensor I/O Zone        Normal   ---F/---C 212F/100C 
 +39  Basic Sensor I/O Zone        Normal   ---F/---C 212F/100C 
 +40  Basic Sensor I/O Zone        Normal    89F/ 32C 149F/ 65C 
 +41  Basic Sensor I/O Zone        Normal    93F/ 34C 149F/ 65C 
 +42  Basic Sensor I/O Zone        Normal    93F/ 34C 149F/ 65C 
 +43  Basic Sensor I/O Zone        Normal    87F/ 31C 149F/ 65C 
 +44  Basic Sensor I/O Zone        Normal    89F/ 32C 149F/ 65C 
 +45  Basic Sensor I/O Zone        Normal    91F/ 33C 149F/ 65C 
 +46  Basic Sensor I/O Zone        Normal   ---F/---C 212F/100C 
 +47  Basic Sensor System Board    Normal   109F/ 43C 176F/ 80C 
 +48  Basic Sensor System Board    Normal    71F/ 22C 149F/ 65C 
 +49  Basic Sensor Chassis         Normal   102F/ 39C 176F/ 80C 
 +
 +ID     TYPE        LOCATION      STATUS  REDUNDANT FAN SPEED 
 +  Var. Speed   System Board    Normal     Yes     Normal    6)
 +  Var. Speed   System Board    Normal     Yes     Normal    6)
 +  Var. Speed   System Board    Normal     Yes     Normal    6)
 +  Var. Speed   System Board    Normal     Yes     Normal    6)
 +  Var. Speed   System Board    Normal     Yes     Normal    6)
 +  Var. Speed   System Board    Normal     Yes     Normal    6)
 +
 +ID     TYPE        LOCATION      STATUS  REDUNDANT 
 +  Standard     Pwr. Supply Bay Normal     Yes      
 +  Standard     Pwr. Supply Bay Normal     Yes      
 +</code>
 +</WRAP>
 +<WRAP prewrap center>
 +<code>
 +# /usr/sbin/hpssacli ctrl slot=0 show config
 +
 +Smart Array P420i in Slot 0 (Embedded)    (sn: 00143803116F5A0)
 +
 +
 +   Internal Drive Cage at Port 1I, Box 1, OK
 +
 +   Internal Drive Cage at Port 2I, Box 0, OK
 +   array A (SAS, Unused Space: 0  MB)
 +
 +
 +      logicaldrive 1 (279.4 GB, RAID 1, OK)
 +
 +      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)
 +      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)
 +
 +   SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380  (WWID: 500143803116F5AF)
 +</code>
 +</WRAP>
 +
 +  * Status script ready for cron
 +<WRAP prewrap center>
 +<code>
 +# apt-get install sendemail
 +
 # nano -w Status.sh # nano -w Status.sh
 </code> </code>
 </WRAP> </WRAP>
 <WRAP prewrap center> <WRAP prewrap center>
-<code sh>+<code bash>
 #!/bin/bash #!/bin/bash
  
Line 45: Line 139:
 </code> </code>
 </WRAP> </WRAP>
 +
 
 
hypervisor/hpman1404.txt · Last modified: 2015/09/10 16:07 by giancarlo

Developers: CNR IRCrES IT Office and Library
Giancarlo Birello (giancarlo.birello _@_ ircres.cnr.it) and Anna Perin (anna.perin _@_ ircres.cnr.it)
DigiBess is licensed under: Creative Commons License
Recent changes RSS feed Creative Commons License Valid XHTML 1.0 Valid CSS Driven by DokuWiki
Drupal Garland Theme for Dokuwiki